Tank Level Sensing PUT-FSW-xx.x and TSI-10 Click on image to
enlarge
|
|
|
The PUT-FSW-xx.x is a flange mount pickup tube designed for installation in the side wall
of a tank. The xx.x represents tube length in inches cut at factory. The TSI-10 is the tank level interface wired to MCP. For tank depths to 40". See TSI-50
for tanks to 200".
|
|
Tank Level Sensing PUT-F-xx
and TSI-10 Click on image to enlarge
|
|
|
The PUT-F-xx is a flange mount pickup tube designed for tanks without welded in threaded
hubs. xx represents tube length in inches cut at factory. The TSI-10 is the tank level interface wired to MCP. For tank depths to 40". See TSI-50
for tanks to 200".
|
|
Tank Level Sensing PUT-H-xx
and TSI-10 Click on image to enlarge
|
|
|
The PUT-H-xx is a Hub mount pickup tube designed for tanks with welded in threaded hubs.
xx represents tube length in inches cut at factory. The TSI-10 is the tank level interface wired to MCP. For tank depths to 40". See TSI-50
for tank depths to 200"
|
|
Tank Level Sensing PUT-F-xx and TSI-50 Click on image to enlarge
|
|
|
The PUT-F-xx is a flange mount pickup tube designed for tanks without welded in threaded
hubs. xx represents tube length in inches cut at factory. The TSI-50 is the tank level interface wired to MCP. For Tanks between 40" and 200".
|
|
Tank Level Sensing PUT-H-xx
and TSI-50 Click on image to enlarge
|
|
|
The PUT-H-xx is a Hub mount pickup tube designed for tanks with welded in threaded hubs.
xx represents tube length in inches cut at factory. The TSI-50 is the tank level interface wired to MCP. For tanks between 40" and 200"
deep.
|
|
Temperature Sensing Interface
TMSI-F1 Click on image to
enlarge
|
|
|
The TMSI-F1 Temperature sensing interface calibrated in degrees fahrenheit.
|
|
AC Voltage Sensing Interface
ACVSI-120 Click on image to enlarge
|
|
|
The ACVSI-120 The AC voltage sensing interface includes both L1 and L2 sensing. It comes
with a 3ft cable for wiring to circuit breakers (Not included) in the distribution panel. Optical isolation in the
interface assures no line voltages on the control wiring.
|
|
AC Current Sensing Interface
ACISI-50 Click on image to enlarge
|
|
|
The ACISI-50 The AC current sensing interface includes a 50amp donut CT for monitoring
current levels in one leg of the AC supply line. For monitoring in both L1 and L2 you will need two. The ACSI-50 is
required for the load shedding option of the MCP-500-RV.
|
|
AC Current Sensing Interface
ACISI-100 Click on image to enlarge
|
|
|
The ACISI-100 is used in vessels using 100 amp 120/250 volt services. It includes
a 100 amp donut CT for monitoring current levels in one leg of the AC supply line. For monitoring in both L1 and L2 you will
need two. Two ACSI-100 or 50's are required for the load shedding option of the MCP-500-RV. Contact factory
for vessels with three phase service.
|
|
DC Voltage Sensing Interface
DCV-12 Click on image to enlarge
|
|
|
The DCV-12 is the DC voltage sensing interface for both the house and engine battery
banks
|
|
DC Voltage Sensing Interface
DCV-24 Click on image to enlarge
|
|
|
The DCV-24 is the DC voltage sensing interface for both the house and engine battery
banks where the banks are 24 volt.
|
|
DC Current Sensing Interface
DCI-200 Click on image to
enlarge
|
|
|
The DCI-200 includes a 200amp DC shunt for monitoring the house battery bank current draw.
|
|
Propane Tank Level Sensing Interface
PSI-90
Click on image to enlarge
|
|
|
The PSI-90 is an interface between a standard 0-90 ohm Rochester Gauges Twin Site sender
and the processor. The gauge is shown in the photo for clearification purposes only and is not supplied with the interface.
They are easily puchased from your local gas company if your tank does not already have one.
|
|
AC Power Sensing Module
ACSM-3
Click on image to enlarge
|
|
|
The ACSM-3 is a power sensing module that connects in to power points at the automatic
transfer switch. It lets the MCP know where and if power is being supplied from the generator or shore
power and is used in conjunction with the GSM-2 for the automatic control of the generator.
|
|
Generator Starting Module
GSM-2 Click
on image to enlage
|
|
|
The GSM-2 is used to start and stop the generator automatically. It is designed to
be used with any generator with automatic shutdowns and momentary glow, start and stop controls. The ACSM-3 is also required
for automatic generator control.
|
|
Load Shedding Module
LSM-2 Click on image to enlage
|
|
|
The LSM-2 is the load shedding module that allows the MCP to switch non-essential loads
of up to 20 amps off when an overload condition occurs. It can switch two circuits one on line 1 and one on
line 2. The LSM-2 also includes control switching for back-up heating.
|
|