The MCP-200-M is the heart of the monitor and control system.
It has a 6' LCD touch screen that allows you to switch from one screen to another with a simple touch of a box displayed
on the screen. All of the screen below are included in this model.

Features included in the
MCP-200-M
Tank level monitoring of up to four water and two fuel tanks. They can be
set up according to your requirements. All of these tanks can be linearized with a simple set up procedure. Alarm levels
are factory set for each tank.
AC voltage and current monitoring with alarm set points for low voltage and
high load current.
DC voltage monitoring of engine and house batteries and current monitoring of the house
batteries. Alarm set points are included for low battery voltages.
Temperature monitoring of up to three refrigeration
compartments with on screen adjustment of high and low temperature alarm set points.
Advanced twenty five
point tank linearizing program for scaling all tanks.
The MCP-200-M can be installed complete with all of the
sensing interfaces from the beginning or added to in the future. However the MCP-200-M has no provisions for generator
starting or load shedding so if you think you might want these features look into going with the MCP-500-M
Tank Level Screen Click
on image to enlarge
|
|
|
The Tank Level Screen displays full scale analog display of up to four tanks, we can label them
according to your requiremnets. Alarm points are set in the program for low and/or high levels. When an alarm condition occurs
the program changes to the alarm screen and the beeper sounds for ten seconds.
|
Fuel Level Screen Click
on image to enlarge
|
|
|
Fuel level screen with full scale analog display of port and starboard fuel tanks. Alarm
points are set in the program for low fuel. When an alarm condition occurs the program changes to the alarm screen and the
beeper sounds for ten seconds.
|
AC Power Monitor Screen Click
on image to enlarge
|
|
|
The AC power monitor screen monitors voltage and current in both L1 and L2 legs. The program
has alarm set points for low voltage and high current. When an alarm condition occurs the screen changes to the alarm screen and
a beeper sounds for ten seconds. The MCP-500 program has provisions to start the generator on loss of AC voltage and
to shed one level of load when the AC current is too high.
|
DC Power Monitor Screen Click on image to enlarge
|
|
|
The DC power monotor page displays house and engine battery voltages and house battery load current.
Alarms are set in the program at low DC voltages of both batteries. When an Alarm condition occurs the screen automatically
changes to the alarm screen and a beeper sounds for ten seconds.
|
Temperature Monitor Screen Click on
image to enlarge
|
|
|
The temperature monitor screen displays temperatures in three compartments.
High and low alarm set points can be set on the screen. When an alarm condition occurs the screen changes to the alarm screen
and the beeper sounds for ten seconds.
|
Alarm Panel Click on image to enlarge
|
|
|
The Alarm Panel automatically displays when an alarm condition is first sensed by the
processor. A beeper will sound for ten seconds to notify of a new alarm condition. After ten seconds the alarm gets
placed in the alarm annunciator field until the alarm condition is cleared. The silence alarm button can be activated at
any time to silence the beeper.
|
Bilge Alarm Screen Click
on image to enlarge
|
|
|
The bilge alarm screen indicates high bilge water in three bilge compartments. When a
bilge alarm comes into the system the screen automatically changes to the bilge alarm screen and a continuous alarm sounds
until the condition is cleared.
|
Set up Screen Click on image to enlarge
|
|
|
The Set Up Screen is used for linearizing the six tanks to be monitored by the
MCP. An advanced twenty five point linearization program scales the tanks so actual tank volume is displayed
on the screen instead of tank levels. This is provided for the marine MCP's because of the irregular tank shapes that
are used in boats.
|

The dimensional information provided above show cutout size and space required
behind the unit. Please call or email for any other information needed.
|