The MCP-200-RV is the heart of the monitor and control system. It has a
6' LCD touch screen that allows you to switch from one screen to another with a simple touch of a box displayed on
the screen. All of the screens below are included in this model.

Features included in the MCP-200-RV
Tank level monitoring
of fresh, grey and black water tanks as well as propane tank level. Alarm levels can be set for each tank.
AC voltage and current monitoring with
alarm set points for low voltage and high load current.
DC voltage monitoring of engine and house batteries and current monitoring of the
house batteries. Alarm set points are included for low battery voltages.
Temperature monitoring of outside, inside and the basement with alarms when the inside
or basement temperatures fall below freezing.
The MCP-200-RV can be installed complete with all of the sensing interfaces
from the beginning or added to in the future. However this model has no provisions for generator starting or load
shedding so if you think you might want these features look at the MCP-500-RV.
Tank Level Screen Click
on image to enlarge
|
|
|
Tank level screen with full scale analog display of fresh, grey and black water and propane
level. Alarm points are set in the program for low fresh water and propane as well as high grey and black water. When an alarm
condition occurs the program changes to the alarm screen and the beeper sounds for ten seconds.
|
AC Power Monitor Screen
Click on image to enlarge
|
|
|
The AC power monitor screen monitors voltage and current in both L1 and L2 legs. The program
has alarm set points for low voltage and high current. When an alarm condition occurs the screen changes to the alarm screen and
a beeper sounds for ten seconds.
|
DC Power Monitor Screen
Click on image to enlarge
|
|
|
The DC power monitor page displays house and engine battery voltages and house battery load current.
Alarms are set in the program at low DC voltages of both batteries. When an Alarm condition occurs the screen automatically
changes to the alarm screen and a beeper sounds for ten seconds.
|
Temperature Monitor Screen Click on
image to enlarge
|
|
|
The temperature monitor screen displays temperatures at three locations. For a motorhome
it would monitor inside, outside and basement temps. The program has alarm set points for inside and basement
temps at 32 deg. When an alarm condition occurs the screen changes to the alarm screen and the beeper sounds for ten
seconds.
|
Alarm Panel Click on image to enlarge
|
|
|
The Alarm Panel automatically displays when an alarm condition is first sensed by the
processor. A beeper will sound for ten seconds to notify of a new alarm condition. After ten seconds the alarm gets
placed in the alarm annunciator field until the alarm condition is cleared. The silence alarm button can be activated at
any time to silence the beeper.
|

The dimensional information provided above show cutout size and space required
behind the unit. Please call or email for any additonal information.
|